How to improve the imaging quality of endoscope camera module manufacturers

Comments ยท 258 Views

endoscope camera module manufacturers https://www.hengal-tech.com/p-Camera-Module/4.html

endoscope camera module manufacturers are equipped with built-in CCD cameras, so that we can obtain high-definition images, which is inconvenient for us to inspect. The equipment conducts self-inspection in the pipeline, but the equipment is prone to some application failures, for example, the environment is too dark, which is not conducive to our collection of images and can only obtain the most unclear photos.

When endoscope camera module manufacturers practice electronic endoscope hole detection, due to the influence of light intensity, background, focal length, noise, etc. in the pipeline, the quality of the images obtained by the equipment will be different. image, we need to take different image solutions to improve the quality of the image. When the electronic endoscope uses the hole probe to obtain the image, some of them contain noise, because the cause of the noise will also cause the degradation of the image quality.

We can use median filtering to filter noise, protect the edge information of the picture, and improve the final quality of the picture. If the edge problem of the obtained picture is more obvious, we can solve it directly through the current image to improve the quality of the picture. If the background and the object are significantly different because the noise of the hole probe image is small, the edge can also be extracted directly.

endoscope camera module manufacturers The size of the CCD directly determines the size of the MOS. Endoscope camera module manufacturers CCD of the same size, when the volume of the MOS increases, of course, the number of pixels of the CCD will decrease, and its ability to accommodate charges will be stronger, and the static size of the CCD will increase, that is, the exposure latitude will be larger. As a result, endoscope camera module manufacturers CCD can feel the slight change of light, and the pictures taken are naturally rich.

Conversely, when the size of the MOS decreases and the number of pixels of the CCD increases, the ability to store electric charges decreases, and it is easy to cause the phenomenon of electric charge overflow, which leads to the appearance of noise in the picture. Therefore, we often find that the upgraded version of a certain DC improves the resolution of the CCD, but the size of the endoscope camera module manufacturers CCD has not changed, and the sharpness of the photos taken in has improved, but the signal-to-noise ratio has decreased, and the loss of details has increased. The overall image quality has dropped instead.